jQuery Mobile Framework
Search Home >> Standards Wordwide >> Chinese Standards(GB) >> GB/Z 20965-2007 Control network HBES technology specification - Home and building control system

GB/Z 20965-2007 Control network HBES technology specification - Home and building control system

Standard Number:  GB/Z 20965-2007
Title:  Control network HBES technology specification - Home and building control system
Language:  Simplified Chinese
Publication Date:  2007/7/9
Execute Date:  2007/10/1
Revocatory Date:  2013/12/15
Adopted International Standard:  EN 50090:2005
Standard Type:  Generalites
International Classification for Standards (ICS)MANUFACTURING ENGINEERING>>Industrial automation systems
Publisher:  Chinese Standards(GB)
Price:446.40  
Number of Pages:372  

Description:This guiding technical document describes the event-based control of distributed bus system, the overall structure of the hbes, provides for hbes management discipline, as well as against the media and media related requirements, product consistency test and evaluation criteria, standards and installation requirements.  
Cross References:GB/T 2423.3-1993 Basic environmental testing procedures for electric and electronic products--Test Ca:Damp heat,steady state;GB/T 2423.5-1995 Environmental testing for electric and electronic products--Part 2:Test methods--Test Ea and guidance:Shock;GB/T 9387;GB/T 15157.7-2002 Connectors for frequencies below 3MHz for use with printed boards--Part 7:Detail specification for connectors,8-way,including fixed and free connectors with common mating features,with assessed quality;GB/T 17045-2006 Protection against electric shock - Common aspects for installation and equipment;GB/T 17626.5-1999 Electromagnetic compatibility--Testing and measurement techniques--Surge immunity test;GB/T 17737.1-2000 Radio-frequency cables--Part 1:Generic specification--General,definitions,requirements and test methods;GB/T 18380.1-2001 Tests on electric cables under fire conditions--Part 1:Test on a single vertical insulated wire or cable;GB/T 20438-2006;ISO/IEC 15018;IEC 60050-191 Amd.1 Ed. 1.0 Amendment 1 - International Electrotechnical Vocabulary. Chapter 191: Dependability and quality of service;IEC 60189-2 Amd.1 Ed. 3.0 Amendment 1 - Low-frequency cables and wires with PVC insulation and PVC sheath. - Part 2: Cables in pairs, triples, quads and quintuples for inside installations;IEC 60364-4-44 Ed. 2.0 Cor.1 Corrigendum 1 - Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances;IEC 60670-1-2002 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements;IEC 60754-2 Ed. 2.0 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity;IEC 60807-2 Amd.1 Ed. 2.0 Amendment 1 - Rectangular connectors for frequencies below 3 MHz - Part 2: Detail specification for a range of connectors, with assessed quality, with trapezoidal shaped metal shells and round contacts - Fixed solder contact types;IEC 60807-3 Ed. 1.0 Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction;EN ISO 9000 series;EN ISO 16484-2;EN 50065 series;EN 50065-1-2001 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances;EN 50065-4-6-2004 signalling on low-voltage electrical installations in the frequency range 3 khz to 148,5 khz -- part 4-6: low voltage decoupling filters - phase coupler;EN 50065-7-2001 signalling on low-voltage electrical installations in the frequency range 3 khz to 148,5 khz -- part 7: equipment impedance;EN 50081-1;EN 50082-1;EN 50083 series;EN 50160-1999 Voltage characteristics of electricity supplied by public distribution systems;EN 50173-1-2002 Information technology - Generic cabling systems - Part 1: General requirements and office areas;EN 50174-1-2000 Information technology - Cabling installation - Part 1: Specification and quality assurance;EN 50174-2-2000 Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings;EN 50290 series;EN 55016-1-2-2004 specification for radio disturbance and immunity measuring apparatus and methods -- part 1-2: radio disturbance and immunity measuring apparatus - ancillary equipment - conducted disturbances;EN 55022;EN 55022+A1;EN 55024;EN 60068-2-1;EN 60068-2-2 Environmental testing - Part 2-2: Tests - Test B: Dry heat;EN 60068-2-6 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal);EN 60068-2-14 Environmental Testing Part 2: Tests - Test N: Change of Temperature IEC 60068-2-14: 1984 + A1: 1986; Supersedes HD 323.2.14S2:1997;EN 60068-2-30 Environmental Testing - Part 2: Tests - Test Db and Guidance: Damp Heat, Cyclic (12 + 12 Hour Cycle) IEC 60068-2-30: 2005;EN 60603-8;EN 60715;EN 60721-3-3;EN 60742;ENV 61000-2-2;EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current greater than or equal to 16 A per phase) IEC 61000-3-2:2005;EN 61000-3-3/prA11-1995 Electromagnetic compatibility (EMC) - Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current 16 A;EN 61000-4-2/prAA-2000 Amendment to IEC 61000-4-2: A test set-up for portable and/or double insulated table top equipment;EN 61000-4-3 Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test Incorporates Amendment A1: 2008;EN 61000-4-4/prAB-2000 Amendment to IEC 61000-4-4 (1995);EN 61000-4-6 Revision 96 Electromagnetic Compatibility (Emc) - Part 4-6: Testing And Measurement Techniques - Immunity To Conducted Disturbances, Induced By Radio-Frequency Fields (Iec 61000-4-6:2013) - Revision 96;Tr  
Catalog: Preface Ⅹ Ⅲ introduction Ⅹ Ⅴ range 1 2 normative reference file 1 3 definition of terms and definitions 3.1 4 GB/T9387 4 3.2 this instructional technology files to determine the definition of 4 4 acronyms 17 5 system overview 21 5.1 architecture May 21 21 5.1.3. 1.1 an overview of the 21 5.1.2 HBES reference model reference points and the specific reference point of the functional group 28 5.1.4 ensuring interface standardization 29 5.1.5 system features 31 34 5.2.1 overview 5.2 5.2 general technical requirements 234 5.2335 5.2438 5.2539 5.2652 5HBES 3 Article 54 5.3.1 general functional safety requirements summarized 54 5.3.2 in 54 5.3.3 functional safety requirements 56 6 features 59 6.1 application introduction to the structure of 59 6.1.1 59 6.1.2 structure 60 6.2 1 class H BES user process 61 6.2.1 overview 61 6.2.2 object model 61 6.2.3 group object services 61 6.2.4 interface object server 61 7 68 68 7.1 1 class HBES application layer media independent floor 7.1.1 overview 68 7 1.2 communication mode and service primitives 68 7.1.3 application layer protocol data unit (APDU) 122 69 72 7.1.5 7.1.4 application layer service application layer parameters 7.2 1 class HBES transport layer, network layer, and the public portion of the data link layer 7 122. 2.1 overview of 122 7.2.2 has nothing to do the physical layer and data link layer needs 122 7.2.3 network layer demands 7.2.4 transport layer 129 137 8 media and media related layer 157 8.1 1 class HBES powerline 157 8.1.1 overview of 1 57 8.1.2 requirement for class 1 HBES power line PL110 157 8.1.3 requirement for class 1 HBES power line PL132 174 8.2, based on class 1 HBES network twisted-pair 183 8.2.1 overview 183 8.2.2 HBE to 1 kind S twisted-pair cable type 0 (TP0) request to class 1 183 8.2.3 HBES twisted-pair cable type 1 (TP1  64 and TP1  256), the requirements of the 200-9 system management management discipline overview 229 9.1 229 9.2 229 9.2 network management procedures Overview. 1 229 9.2.2 NM_IndividualAddress_Read 229 9.2.3 NM_IndividualAddress_Write 230 9.2.4 NM_SerialNumberDefa ultIA_Scan 232 9.2.5 NM_IndividualAddress_SerialNumber_Read 233 9.2.6 NM_IndividualAddress_SerialNumber_Writ e 233 9.2.7 NM_DomainAddress_Read 234 9.2.8 NM_DomainAddress_Write 235 9.2.9 NM_DomainAddress_Scan 237 9.2 .10 NM_Router_Scan 238 9.2.11 NM_SubnetworkDevices_Scan 239 9.2.12 NM_SubnetworkAddress_Read 239 9.2.13 NM_ IndividualAddress_Reset 240 9.2.14 NM_IndividualAddress_Scan 241 9.2.15 NM_IndividualAddress_Check 241 9.2. 16 NM_IndividualAddress_Check_LocalSubnetwork 242 9.2.17 NM_GroupAddress_Check 243 9.2.18 NM_FunctionalBlock _Scan 244 9.3 equipment management discipline 244 9.3.1 overview 244 9.3.2 general exception handling 244 9.3.3 DM_Connect 244 9.3.4 DM_Disconnect 9.3.5 246 D M_Authorize 247 9.3.6 DM_SetKey 247 9.3.7 DM_Restart 248 9.3.8 DM_Delay 248 9.3.9 DM_IndividualAddressRead 249 9.3.10 DM_IndividualAddressWrite 249 9.3.11 DM_DomainAddressRead 249 9.3.12 DM_DomainAddressWrite 249 9.3.13 DM_ProgMode_Switch 249 9.3.14 DM_GroupObject_Link_Read 250 9.3.15 DM_GroupObject_Link_Write 251 9.3 .16 DM_MemWrite 251 9.3.17 DM_Mem  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  604KB
Tile in English:  Control network HBES technology specification - Home and building control system