jQuery Mobile Framework
Search Home >> Standards Wordwide >> Australia Standards(AS) >> AS/NZS 61347.1-2002 lamp controlgear - general and safety requirements (iec 61347-1:2000, mod)

AS/NZS 61347.1-2002 lamp controlgear - general and safety requirements (iec 61347-1:2000, mod)

Standard Number:  AS/NZS 61347.1-2002
Title:  lamp controlgear - general and safety requirements (iec 61347-1:2000, mod)
Language:  English
Replaced by Standard:  AS/NZS 61347.1:2016

Replacing Standard:  DR 01302 CP

Publication Date:  2002/8/27
Status:  Current
International Classification for Standards (ICS)ELECTRICAL ENGINEERING>>Lamps and related equipment>>Lamps in general
CCS Classification for StandardsThe electrician>>Electric lighting>>General lamps and lanterns
Publisher:  Australia Standards(AS)
Price:  
Number of Pages:50P.;A4  

Description:this part of as/nzs 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 v and/or a.c. supplies up to 1 000 v at 50 hz or 60 hz. this standard also covers lamp controlgear for lamps which are not yet standardized. tests dealt with in this standard are type tests. requirements for testing individual lamp controlgear during production are not included. requirements for semi-luminaires are given in as/nzs 60598.1. in addition to the requirements given in this standard, annex b sets out general and safety requirements applicable to thermally protected lamp controlgear. annex c sets out additional general and safety requirements as they apply to electronic lamp controlgear with means of protection against overheating. note – examples of products covered by this standard are electronic starters, ballasts and electronic converters. dimmers, iron core transformers (if not covered by 61347.2) are not included in this standard.  
Catalog:Document Contents
AS/NZS 61347.1:2002 LAMP CONTROLGEAR - GENERAL AND SAFETY REQUIREMENTS (IEC 61347-1-2000 lamp controlgear - part 1: general and safety requirements first edition; amendment 1: 9/2003,...
PREFACE
CONTENTS
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
3.1 Lamp controlgear
3.1.1 Built-in lamp controlgear
3.1.2 Independent lamp controlgear
3.1.3 Integral lamp controlgear
3.2 Ballast
3.2.1 d.c. supplied electronic ballast
3.2.2 Reference ballast
3.3 Reference lamp
3.4 Calibration current of a reference ballast
3.5 Supply voltage
3.6 Working voltage
3.7 Design voltage
3.8 Voltage range
3.9 Supply current
3.10 Live part
3.11 Type test
3.12 Type-test sample
3.13 Circuit power factor
3.14 High power factor ballast
3.15 Rated maximum temperature
3.16 Rated maximum operating temperature of a lamp controlgear winding
3.17 Rectifying effect
3.18 Test duration of endurance test
3.19 Degradation of insulation of a ballast winding
3.20 Ignitor
3.21 Protective earth (ground)
3.22 Functional earth (ground)
3.23 Frame (chassis)
4 General requirements
5 General notes on tests
6 Classification
7 Marking
7.1 Items to be marked
7.2 Durability and legibility of marking
8 Terminals, cables and cords
9 Provisions for protective earthing
9.1 Protective earth (ground). Symbol 417C-IEC-5019
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Construction
15.1 Wood, cotton, silk, paper and similar fibrous material
15.2 Printed circuits
16 Creepage distances and clearances
17 Screws, current- carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
Annex A - Test to establish whether a conductive part is a live part which may cause an e...
Annex B - Particular requirements for thermally protected lamp controlgear
B.1 Introductory remark
B.2 Scope
B.3 Definitions
B.4 General requirements for thermally protected lamp controlgear
B.5 General notes on tests
B.6 Classification
B.7 Marking
B.8 Thermal endurance of windings
B.9 Lamp controlgear heating
Annex C - Particular requirements for electronic lamp controlgear with means of protectio...
C.1 Scope
C.2 Definition
C.3 General requirements for electronic lamp controlgear with means of protection against...
C.4 General notes on tests
C.5 Classification
C.6 Marking
C.7 Limitation of heating
Annex D - Requirements for carrying out the heating tests of thermally protected lamp con...
D.1 Test enclosure
D.2 Heating of enclosure
D.3 Lamp controlgear operating conditions
D.4 Lamp controlgear position in the enclosure
D.5 Temperature measurements
Annex E - Use of constant S other than 4 500 in tw tests
Annex F - Draught-proof enclosure
Annex G - Explanation of the derivation of the values of pulse voltages
Annex H - Tests
H.1 Ambient temperature and test room
H.2 Supply voltage and frequency
H.3 Electrical characteristics of lamps
H.4 Magnetic effects
H.5 Mounting and connection of reference lamps
H.6 Reference lamp stability
H.7 Instrument characteristics
H.8 Invertor power sources
H.9 Reference ballast
H.10 Reference lamps
H.11 Test conditions
H.12 Lamp controlgear heating
Bibliography
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  517KB
Tile in English:  lamp controlgear - general and safety requirements (iec 61347-1:2000, mod)

Full Text Information