jQuery Mobile Framework
Search Home >> American Standards >> American Society for Testing Material (ASTM) >> ASTM F710-2008 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring

ASTM F710-2008 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring

Standard Number:  ASTM F710-2008
Title:  Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring
Language:  English
Replaced by Standard:  ASTM F710-11

Execute Date:  2008/1/1
Status:  Withdrawn
Publisher:  American Society for Testing Material (ASTM)
Price:  
Number of Pages:6P.;A4   

Description:

1.1 This practice covers the determination of the acceptability of a concrete floor for the installation of resilient flooring.

1.2 This practice includes suggestions for the construction of a concrete floor to ensure its acceptability for installation of resilient flooring.

1.3 This practice does not cover the adequacy of the concrete floor to perform its structural requirements.

1.4 This practice covers the necessary preparation of concrete floors prior to the installation of resilient flooring.

1.5 This practice does not supersede in any manner the resilient flooring or adhesive manufacturer''s written instructions. Consult the individual manufacturer for specific recommendations.

1.6 Although carpet tiles, carpet, wood flooring, coatings, films, and paints ae not specifically intended to be included in the category of resilient floor coverings, the procedures included in this practice may be useful for preparing concrete floors to receive such finishes.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 5.1, 7.1.1, and 7.1.2 for specific warning statements.

1.8 The values stated in inch-pound units are to be regarded as standard. The values in parentheses are mathematical conversions to SI units and are provided for information only.

  
Cross References:117R;ASTM C109/C109M;ASTM C472;ASTM D4259;ASTM D4263;ASTM D4397;ASTM E1155;ASTM F710;ASTM F2170;ASTM E1486;ASTM E1745;SPECTEXT Guide Spec Section 03346;Recommended Work Practices;ASTM F1869;ASTM F141  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  126KB
Tile in English:  Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring

Full Text Information