AS 2264-1995 A.C.insulation-enclosed switchgear and controlgear for rated voltages above 1 KV and up to and including 38 KV

Standard Number:  AS 2264-1995
Title:  A.C.insulation-enclosed switchgear and controlgear for rated voltages above 1 KV and up to and including 38 KV
Language:  English
Publication Date:  1995/4/7
Execute Date:  1995/8/5
Adopted International Standard:  IEC 60466 Amd.1 Ed. 2.0 Equivalent IEC 60466 Ed. 2.0 Equivalent
Status:  Withdrawn
Publisher:  Australia Standards(AS)
Price:  
Number of Pages:46P.;A4  

Description:Applies to factory-assembled insulation-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 38 kV for indoor installation and for service frequencies up to and including 60 Hz. This Standard is equivalent in technical content but does not fully correspond in presentation to IEC 466-1987 and Amendment 1-1994.  
Catalog:Document Contents
AS 2264-1995 A.C. INSULATION-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOV...
PREFACE
CONTENTS
1. Scope
2. Normal and special service conditions
3. Definitions
3.101 Switchgear and controlgear
3.102 Insulation-enclosed switchgear and controlgear
3.103 Transport unit
3.104 Functional unit
3.105 Insulation enclosure
3.106 Insulation-embedded component
3.107 Component
3.108 Shutter
3.109 Removable part
3.110 Withdrawable part
3.112 Service position/connected position (of a removable part)
3.113 Earthing position (of a removable part)
3.114 Test position (of a withdrawable part)
3.115 Disconnected position (of a withdrawable part)
3.116 Removed position (of a removable part)
3.117 Main circuit
3.118 Auxiliary circuit
3.119 Rated value
3.120 Degree of protection
3.121 Ambient air temperature (of insulation-enclosed switchgear and controlgear)
3.122 Disruptive discharge
4. Rating
5. Design and construction
6. Type tests
7. Routine tests
8. Guide to the selection of switchgear and controlgear for service
9. Information to be given with enquiries, tenders and orders
10. Rules for transport, storage, erection and maintenance
APPENDIX AA - INTERNAL FAULT
AA1. Introduction
AA2. Types of accessibility
AA3. Test arrangement
AA4. Current and voltage applied
AA5. Test procedure
AA6. Assessment of the test
AA7. Test report
APPENDIX BB - HUMIDITY TEST
BB1. General
BB2. Test procedure and test conditions
BB3. Test criteria and evaluation
APPENDIX CC - RATED INSULATION LEVEL FOR SERIES II
APPENDIX DD - GUIDE FOR DIELECTRIC TESTS AFTER ERECTION ON SITE
APPENDIX ZZ - LIST OF VARIATIONS BETWEEN THIS STANDARD AND IEC 466
APPENDIX ZA - ITEMS SUBJECT TO AGREEMENT BETWEEN MANUFACTURER AND USER
Amendment 1
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  346KB
Tile in English:  A.C.insulation-enclosed switchgear and controlgear for rated voltages above 1 KV and up to and including 38 KV