jQuery Mobile Framework
Search Home >> Standards Wordwide >> International Electrotechnical Commission (IEC) >> IEC 61914 Ed. 1.0 Cable cleats for electrical installations

IEC 61914 Ed. 1.0 Cable cleats for electrical installations

Standard Number:  IEC 61914 Ed. 1.0
Title:  Cable cleats for electrical installations
Language:  English and French
Replaced by Standard:  IEC 61914 Ed. 2.0

Status:  Current
International Classification for Standards (ICS)ELECTRICAL ENGINEERING>>Electrical accessories>>Conduits for electrical purposes
Publisher:  International Electrotechnical Commission (IEC)
Price:  
Number of Pages:57  

Description:IEC 61914-2009 Cable cleats for electrical installations specifies requirements and tests for cable cleats and intermediate restraints used for securing cable in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables.  
Catalog:Document Contents
English
CONTENTS
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
5 General notes on tests
6 Classification
6.1 According to material
6.2 According to maximum and minimum temperature
6.3 According to resistance to impact
6.4 According to type of retention or resistance to electromechanical forces or both
6.5 According to environmental influences
7 Marking and documentation
7.1 Marking
7.2 Durability and legibility
7.3 Documentation
8 Construction
9 Mechanical properties
9.1 Requirements
9.2 Impact test
9.3 Lateral load test
9.4 Axial load test
9.5 Test for resistance to electromechanical force
10 Fire hazards
10.1 Flame propagation
10.2 Smoke emission
10.3 Smoke toxicity
11 Environmental influences
11.1 Resistance to ultraviolet light
11.2 Resistance to corrosion
12 Electromagnetic compatibility
12.1 Electromagnetic emission
12.2 Inductive heating
Annex A (informative) Examples of cable cleats
Annex B (informative) Calculation of forces caused by short-circuit currents
Bibliography
Figures
Figure?1 – Typical arrangement for impact test
Figure?2 – Typical arrangement for lateral load test
Figure?3 – Typical arrangement for axial load test
Figure?4 – Typical assemblies for test for resistance to electromechanical force
Figure?5 – Typical arrangement of three cables in close trefoil formation
Figure?6 – Typical arrangement of cables in flat formation
Figure?7 – Typical arrangement of the needle-flame test
Figure?B.1 – Short-circuit current of a far-from-generator short circuit with constant a....
Figure?B.2 – Short-circuit current of a near-to-generator short circuit with decaying a.c...
Figure?B.3 – Two parallel conductors
Tables
Table 1 – Maximum temperature for permanent application
Table 2 – Minimum temperature for permanent application
Table 3 – Impact test values
Table 4 – Resistance to corrosion
Fran?ais
SOMMAIRE
AVANT-PROPOS
1 Domaine d’application
2 Références normatives
3 Termes, définitions et abréviations
4 Exigences générales
5 Généralités sur les essais
6 Classification
6.1 Selon le matériau
6.2 Selon les températures maximale et minimale
6.3 Selon la tenue aux chocs
6.4 Selon le type de maintien ou la tenue aux forces électromécaniques ou encore les deux
6.5 Selon les influences liées à l’environnement
7 Marquage et documentation
7.1 Marquage
7.2 Durabilité et lisibilité
7.3 Documentation
8 Construction
9 Propriétés mécaniques
9.1 Exigences
9.2 Essai de tenue au choc
9.3 Essai de tenue à la charge latérale
9.4 Essai de tenue à la charge axiale
9.5 Essai de tenue aux forces électromécaniques
10 Risques du feu
10.1 Propagation de la flamme
10.2 Emission de fumée
10.3 Toxicité des fumées
11 Influences de l’environnement
11.1 Tenue à la lumière ultraviolette
11.2 Tenue à la corrosion
12 Compatibilité électromagnétique
12.1 Emission
12.2 Echauffement par induction
Annexe A (informative) Exemples de brides de cables
Annexe B (informative) Calcul des forces provoquées par les courants de court-circuit
Bibliographie
Figures
Figure?1 – Configuration type pour l'essai de tenue au choc
Figure?2 – Configuration type pour l'essai de tenue à la charge latérale
Figure?3 – Configuration type pour l'essai de tenue à la charge axiale
Figure?4 – Assemblages type pour l'essai de tenue aux forces électromécaniques
Figure?5 – Configuration type de trois cables en disposition trèfle serré
Figure?6 – Configuration type de cables en disposition en nappe
Figure 7?–?Configuration type pour l'essai au br?leur aiguille
Figure?B.1 – Courant de court-circuit pour un court-circuit loin du générateur avec une c...
Figure?B.2 – Courant de court-circuit pour un court-circuit près du générateur avec une c...
Figure?B.3 – Deux conducteurs parallèles
Tableaux
Tableau 1 – Température maximale en usage permanent
Tableau 2 – Température minimale en usage permanent
Tableau 3 – Valeurs pour l'essai de choc
Tableau 4 – Tenue à la corrosion
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  494KB
Tile in English:  Cable cleats for electrical installations

Full Text Information