Search Home >> Standards Wordwide >> International Electrotechnical Commission (IEC) >> IEC 62271-110 Ed. 2.0 High-voltage switchgear and controlgear - Part 110: Inductive load switching

IEC 62271-110 Ed. 2.0 High-voltage switchgear and controlgear - Part 110: Inductive load switching

Standard Number:  IEC 62271-110 Ed. 2.0
Title:  High-voltage switchgear and controlgear - Part 110: Inductive load switching
Language:  English and French
Replaced by Standard:  IEC 62271-110 Ed. 3.0

Replacing Standard:  IEC 62271-110 Ed. 1.0

Status:  Withdrawn
Publisher:  International Electrotechnical Commission (IEC)
Price:  
Number of Pages:49  

Description:IEC 62271-110-2009 High-voltage switchgear and controlgear - Part 110: Inductive load switching is applicable to a.c. circuit-breakers designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V and applied for inductive current switching with or without additional short-circuit current breaking duties. The standard is applicable to circuit-breakers in accordance with IEC 62271-100 that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents. This second edition cancels and replaces the first edition dated 2005 and constitutes an editorial revision. The main changes from the first edition are that all references to IEC 60694 have been replaced by IEC 62271-1. This standard is to be read in conjunction with IEC 62271-1, first edition, published in 2007, and with IEC 62271-100, second edition, published in 2008. This publication is to be read in conjunction with IEC 62271-1-2007 and IEC 62271-100-2008.  
Catalog:Document Contents
English
CONTENTS
FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Normal and special service conditions
3 Definitions
4 Ratings
4.1 Rated voltage (Ur)
4.2 Rated insulation level
4.3 Rated frequency (fr)
4.4 Rated normal current (Ir) and temperature rise
4.5 Rated short-time withstand current (Ik)
4.6 Rated peak withstand current (Ip)
4.7 Rated duration of short-circuit (tk)
4.8 Rated supply voltage of closing and opening devices and of auxiliary and control circ...
4.9 Rated supply frequency of closing and opening devices and auxiliary circuits
4.10 Rated pressure of compressed gas supply for insulation, operation and/or interruption
5 Design and construction
6 Type tests
6.1 General
6.2 Dielectric test
6.3 Radio interference voltage (r.i.v.) tests
6.4 Measurement of the resistance of the main circuit
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand current tests
6.7 Verification of protection
6.8 Tightness tests
6.9 Electromagnetic compatibility (EMC) tests
6.101 Mechanical and environmental tests
6.102 Miscellaneous provisions for making and breaking tests
6.103 Test circuits for short-circuit making and breaking tests
6.104 Short-circuit test quantities
6.105 Short-circuit test procedures
6.106 Basic short-circuit test duties
6.107 Critical current tests
6.108 Single-phase and double-earth fault tests
6.114 High-voltage motor current switching tests
6.115 Shunt reactor current switching tests
7 Routine tests
8 Guide to selection of circuit-breakers for service
9 Information to be given with enquiries, tenders and orders
10 Rules for transport, storage, installation, operation and maintenance
11 Safety
Bibliography
Figure 1 – Motor switching test circuit and summary of parameters
Figure 2 – Illustration of transient voltages at interruption of inductive current for fi...
Figure 3 ? Reactor switching test ? Basic layout of three-phase test circuit
Figure 4 ? Reactor switching test ? Basic layout of single-phase test circuit
Figure 5 – Illustration of transient voltages at interruption of inductive current for a ...
Table 1 ? Test duties at motor current switching tests
Table 2 – Prospective transient voltage of load circuit including connection to the circu...
Table 3 ? Load circuit 1 test currents
Table 4 – Load circuit 2 test currents
Table 5 – Test duties for reactor current switching tests
Fran?ais
SOMMAIRE
AVANT-PROPOS
1 Généralités
1.1 Domaine d’application
1.2 Références normatives
2 Conditions normales et spéciales de service
3 Définitions
4 Caractéristiques assignées
4.1 Tension assignée (Ur)
4.2 Niveau d’isolement assigné
4.3 Fréquence assignée (fr)
4.4 Courant assigné en service continu (Ir) et échauffement
4.5 Courant de courte durée admissible assigné (Ik)
4.6 Valeur de crête du courant admissible assigné (Ip)
4.7 Durée de court-circuit assigné (tk)
4.8 Tension assignée d'alimentation des dispositifs de fermeture et d'ouverture des circu...
4.9 Fréquence assignée d'alimentation des dispositifs de fermeture et d'ouverture des cir...
4.10 Pression assignée d'alimentation en gaz comprimé pour l'isolement, la manoeuvre et/o...
5 Conception et construction
6 Essais de type
6.1 Généralités
6.2 Essais diélectriques
6.3 Essais de tension de perturbation radioélectrique
6.4 Mesurage de la résistance du circuit principal
6.5 Essais d’échauffement
6.6 Essais au courant de courte durée et à la valeur crête du courant admissible
6.7 Vérification de la protection
6.8 Essais d’étanchéité
6.9 Essais de compatibilité électromagnétique
6.101 Essais mécaniques et climatiques
6.102 Dispositions diverses pour les essais d?établissement et de coupure
6.103 Circuits d?essais pour les essais d?établissement et de coupure en court-circuit
6.104 Caractéristiques pour les essais de court-circuit
6.105 Procédures d?essai en court-circuit
6.106 Séquences d?essais de court-circuit fondamentales
6.107 Essais au courant critique
6.108 Essais de défaut monophasé ou de double défaut à la terre
6.114 Essais d?établissement et de coupure de moteur à haute tension
6.115 Essais d?établissement et de coupure de courant de réactance shunt
7 Essais individuels
8 Guide pour la sélection d’un disjoncteur en service
9 Renseignements à donner dans les appels d'offres, les soumissions et les commandes
10 Règles pour le transport, le stockage, l'installation, la man?uvre et la maintenance
11 Sécurité
Bibliographie
Figure 1 – Circuit d’essai d’établissement et de coupure de moteur et résumé des paramètr...
Figure 2 – Illustration des tensions transitoires lors de la coupure de courant inductif;...
Figure 3 ? Essai d?établissement et de coupure de réactance ? Disposition de principe d?u...
Figure 4 ? Essai d?établissement et de coupure de réactance ? Disposition de principe d?u...
Figure 5 – Illustration des tensions transitoires lors de la coupure du courant inductif ...
Tableau 1 – Séquences d’essais d’établissement et de coupure de courants de moteurs
Tableau 2 ? Tension transitoire présumée du circuit de charge incluant la connexion du di...
Tableau 3 – Courants d’essais pour circuit de charge 1
Tableau 4 – Courants d’essais pour circuit de charge 2
Tableau 5 – Séquences d’essais d’établissement et de coupure de courant de réactance
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  187KB
Tile in English:  High-voltage switchgear and controlgear - Part 110: Inductive load switching

Full Text Information

Related

Top 10

New 10

PC Version