jQuery Mobile Framework
Search Home >> Standards Wordwide >> International Electrotechnical Commission (IEC) >> IEC 62271-205 Ed. 1.0 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV

IEC 62271-205 Ed. 1.0 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV

Standard Number:  IEC 62271-205 Ed. 1.0
Title:  High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
Language:  English and French
Adopted International Standard:  SANS 62271-205 Ed. 1 High-voltage Switchgear And Controlgear - Part 205: Compact Switchgear Assemblies For Rated Voltages Above 52 Kv Ed. 1 (2008) Identical
BS EN 62271-205-2008 Identical
I.S. EN 62271-20
Status:  Current
Publisher:  International Electrotechnical Commission (IEC)
Price:  
Number of Pages:47  

Description:This part of IEC 62271 applies to compact switchgear assemblies consisting of at least one switching device directly connected to, or sharing components with, one or more other devices such that there is an interaction between the functions of the individual devices. Such assemblies are made up of devices defined in 1.101 and are designed, tested and supplied for use as a single unit. The interaction between devices may be due to proximity, sharing of components or a combination of both. The assemblies may contain components of air insulated switchgear (AIS) only or a combination of AIS and gas insulated switchgear (GIS), so called mixed technology switchgear (MTS) and may be delivered entirely prefabricated or partially assembled.  
Catalog:Document Contents
English
CONTENTS
FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Normal and special service conditions
3 Terms and definitions
3.1 General terms
3.2 Compact switchgear assembly
4 Rating
4.1 Rated voltage (Ur)
4.2 Rated insulation level
4.3 Rated frequency (fr)
4.4 Rated normal current (Ir) and temperature rise
4.5 Rated short-time withstand current (Ik)
4.6 Rated peak withstand current (Ip)
4.7 Rated duration of short circuit (tk)
4.8 Rated supply voltage of closing and opening devices and of auxiliary and control cir...
4.9 Rated supply frequency of closing and opening devices and of auxiliary circuits
5 Design and construction
5.3 Earthing of switchgear and controlgear
5.101 Earthing of compact switchgear assemblies and their controlgear
5.102 Pressure relief devices
5.10 Nameplates
5.12 Position indication
5.103 Locking devices for maintenance operation
5.104 Movement of pressurized devices
5.105 Isolating distance for maintenance
6 Type tests
6.1 General
6.2 Dielectric tests
6.3 Radio interference voltage (r.i.v.) test
6.4 Measurement of the resistance of circuits
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand current tests
6.101 Mechanical and environmental tests
7 Routine tests
7.1 Dielectric test on the main circuit
7.2 Tests on auxiliary and control circuits
7.3 Measurement of the resistance of the main circuit
7.101 Functional tests on auxiliary and control circuits
8 Guide to the selection of switchgear and controlgear
8.101 Guide to the selection of compact switchgear assemblies
9 Information to be given with enquiries, tenders and orders
10 Transport, storage, installation, operation and maintenance
10.1 Conditions during transport, storage and installation
10.2 Installation
10.3 Operation
10.4 Maintenance
11 Safety
Annex AA (informative) Explanations of compact switchgear assemblies
Bibliography
Figure AA.1 – Example for type 1
Figure AA.2 – Example for type 2
Figure AA.3 – Example for type 3
Figure AA.4 – Example for type 3
Table 101 – Type tests on the compact switchgear assembly
Fran?ais
SOMMAIRE
AVANT-PROPOS
1 Généralités
1.1 Domaine d'application
1.2 Références normatives
2 Conditions normales et spéciales de service
3 Termes et définitions
3.1 Termes généraux
3.2 Ensemble d’appareillages compact
4 Caractéristiques assignées
4.1 Tension assignée (Ur)
4.2 Niveau d’isolement assigné
4.3 Fréquence assignée (fr)
4.4 Courant assigné en service continu (Ir) et échauffement
4.5 Courant de courte durée admissible assigné (Ik)
4.6 Valeur de crête du courant admissible assigné (Ip)
4.7 Durée de court-circuit assignée (tk)
4.8 Tension assignée d’alimentation des dispositifs de fermeture et d’ouverture et des ci...
4.9 Fréquence assignée d'alimentation des dispositifs de fermeture et d'ouverture et des ...
5 Conception et construction
5.3 Raccordement à la terre de l’appareillage
5.101 Raccordement à la terre des ensembles d'appareillages compacts et de leur appareill...
5.102 Limiteurs de pression
5.10 Plaques signalétiques
5.12 Indicateur de position
6 Essais de type
6.1 Généralités
6.2 Essais diélectriques
6.3 Essai de tension de perturbation radioélectrique
6.4 Mesurage de la résistance des circuits
6.5 Essais d'échauffement
6.6 Essais au courant de courte durée admissible et à la valeur de crête du courant admis...
6.101 Essais mécaniques et d’environnement
7 Essais individuels de série
7.1 Essais diélectriques du circuit principal
7.2 Essais des circuits auxiliaires et de commande
7.3 Mesurage de la résistance du circuit principal
7.101 Essais fonctionnels sur les circuits auxiliaires et de commande
8 Guide pour le choix de l'appareillage
8.101 Guide pour le choix des ensembles d’appareillage compact
9 Renseignements à donner dans les appels d?offres, les soumissions et les commandes
10 Transport, stockage, installation, man?uvre et maintenance
10.1 Conditions à respecter pendant le transport, le stockage et l’installation
10.2 Installation
10.3 Fonctionnement
10.4 Maintenance
11 Sécurité
Annexe AA (informative) Explications concernant les ensembles d?appareillages compacts
Bibliographie
Figure AA.1 – Exemple pour le type 1
Figure AA.2 – Exemple pour le type 2
Figure AA.3 – Exemple pour le type 3
Figure AA.4 – Exemple pour le type 3
Tableau 101 ? Essais de type sur un ensemble d?appareillages compact
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  581KB
Tile in English:  High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV

Full Text Information

Related

Top 10

New 10

PC Version