jQuery Mobile Framework
Search Home >> Standards Wordwide >> International Electrotechnical Commission (IEC) >> IEC 61076-3-110 Ed. 2.0 Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1 000 MHz

IEC 61076-3-110 Ed. 2.0 Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1 000 MHz

Standard Number:  IEC 61076-3-110 Ed. 2.0
Title:  Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1 000 MHz
Language:  English and French
Replaced by Standard:  IEC 61076-3-110 Ed. 3.0

Replacing Standard:  IEC 61076-3-110 Ed. 1.0

Status:  Current
Publisher:  International Electrotechnical Commission (IEC)
Price:  
Number of Pages:37  

Description:IEC 61076-3-110-2012 Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1000 MHz This detail specification covers mechanical and environmental requirements, and electrical transmission requirements for frequencies up to 1 000 MHz. These connectors can be used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801. The connectors are intermateable with IEC 60603-7 series connectors (see 3.3). The connectors are interoperable with IEC 60603-7-7 and IEC 60603-7-71 connectors (see 3.4). The connectors are backward compatible with IEC 60603-7-7 and IEC 60603-7-71 connectors (see 3.5). This second edition cancels and replaces the first edition, issued in 2007, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition- - changes in 4.5 regarding electrical transmission performance i.e. return loss, among other specific changes, in compliance to the requirements of ISO/IEC 11801, - updated text and format to be consistent with the referenced standards, - removal of duplication of requirements in the IEC 60603-7 standard series, introduction of transmission performance testing procedures as specified by IEC 60512-28-100. Keywords- Free connectors, Fixed connectors  
Catalog:Document Contents<" style="border-width:0;" />Document Contents
English
CONTENTS
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Technical information
3.1 Terms and definitions
3.2 Interchangeability level
3.3 Intermateability
3.4 Interoperability
3.5 Backward compatibility
3.6 Complete connectors (pairs)
3.7 Fixed connectors
3.8 Free connectors
3.9 Classification into climate categories
3.10 Clearance and creepage distances
3.11 Current carrying capacity
3.12 Marking
4 Dimensional information
4.1 General
4.2 Isometric view and common features
4.3 Mating information
4.4 Fixed connectors
4.4.1 Fixed connectors common dimensions
4.4.2 Fixed connector styles
4.5 Free connectors
4.6 Terminations
4.7 Mounting information
4.7.1 Mounting information for fixed connectors
4.7.2 Mounting information for free connectors
4.8 Gauges
4.8.1 General
4.8.2 Mechanical function, engaging/separating/insertion/withdrawal force gauges
4.8.3 Probes
4.8.4 Contact resistance gauge
4.8.5 Test panel (for voltage proof test)
4.8.6 Test panel (for EMC/crosstalk, etc.)
5 Characteristics
5.1 General
5.2 Pin and pair grouping assignment
5.3 Climatic category
5.4 Electrical characteristics
5.5 Transmission characteristics
5.5.1 General
5.5.2 Insertion loss
5.5.3 Return Loss
5.5.4 Propagation delay
5.5.5 Delay skew
5.5.6 Near-end crosstalk (NEXT)
5.5.7 Power sum NEXT (for information only)
5.5.8 Far-end crosstalk (FEXT)
5.5.9 Power sum FEXT (for information only)
5.5.10 Transverse conversion loss
5.5.11 Transverse conversion transfer loss
5.5.12 Power sum alien (exogenous) NEXT
5.5.13 Power sum alien (exogenous) FEXT
5.5.14 Coupling attenuation
5.5.15 Transfer impedance
5.6 Mechanical characteristics
6 Test schedule
6.1 General
6.2 Test schedule
6.2.1 Test group EP
Annex A (normative) Gauging requirements
Bibliography
Figures
Figure 1 – Isometric view, fixed 8 and 12 pole and free 8, 12 and 4 pole connectors
Figure 2 – Fixed connector, board mounted, example
Figure 3 – Fixed connector pin and pair grouping assignment(front view of connector)
Table 1 – Climatic categories – selected values
Table 2 – Test group EP
Fran?ais
SOMMAIRE
AVANT-PROPOS
INTRODUCTION
1 Domaine d’application
2 Références normatives
3 Données techniques
3.1 Termes et définitions
3.2 Niveau d’interchangeabilité
3.3 Compatibilité d'accouplement
3.4 Interopérabilité
3.5 Compatibilité amont
3.6 Connecteurs complets (paires)
3.7 Embases
3.8 Fiches
3.9 Classification en catégories climatiques
3.10 Distances d’isolement et lignes de fuite
3.11 Courant admissible
3.12 Marquage
4 Informations relatives aux dimensions
4.1 Généralités
4.2 Vue isométrique et caractéristiques communes
4.3 Informations relatives à l’accouplement
4.4 Embases
4.4.1 Dimensions communes des embases
4.4.2 Modèles d’embase
4.5 Fiches
4.6 Sorties
4.7 Informations de montage
4.7.1 Informations concernant le montage des embases
4.7.2 Informations concernant le montage des fiches
4.8 Calibres
4.8.1 Généralités
4.8.2 Fonction mécanique, calibres de force d'accouplement/de désaccouplement/d'insertion...
4.8.3 Sondes
4.8.4 Calibre de résistance de contact
4.8.5 Panneau d’essai (pour l’essai de tenue en tension)
4.8.6 Panneau d’essai (pour CEM/ diaphonie, etc.)
5 Caractéristiques
5.1 Généralités
5.2 Affectation des broches et des paires
5.3 Catégorie climatique
5.4 Caractéristiques électriques
5.5 Caractéristiques de transmission
5.5.1 Généralités
5.5.2 Perte d'insertion
5.5.3 Affaiblissement de réflexion
5.5.4 Temps de propagation
5.5.5 Dispersion du temps de propagation
5.5.6 Paradiaphonie (NEXT)
5.5.7 Affaiblissement paradiaphonique cumulé (pour information uniquement)
5.5.8 Affaiblissement télédiaphonique (FEXT)
5.5.9 Télédiaphonie de la somme des puissances FEXT cumulées (pour information uniquement)
5.5.10 Perte de conversion transverse
5.5.11 Perte de transfert de conversion transversale
5.5.12 Affaiblissement paradiaphonique exogène cumulé
5.5.13 Affaiblissement télédiaphonique exogène cumulé
5.5.14 Affaiblissement de couplage
5.5.15 Impédance de transfert
5.6 Caractéristiques mécaniques
6 Programme d’essais
6.1 Généralités
6.2 Programme d'essais
6.2.1 Groupe d’essais EP
Annexe A (normative) Exigences de calibre
Bibliographie
Figures
Figure 1 – Vue isométrique, embase 8 et 12 p?les et fiches 8, 12 et 4 p?les
Figure 2 – Embase, enfichable, exemple
Figure 3 – Affectation de groupement de broches et de paires pour embases(vue de face du ...
Tableau 1 – Catégories climatiques – valeurs choisies
Tableau 2 – Groupe d’essais EP
  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  853KB
Tile in English:  Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1 000 MHz

Full Text Information

Related

Top 10

New 10

PC Version