Search Home >> Standards Wordwide >> International Electrotechnical Commission (IEC) >> IEC 62271-102 Ed. 1.0 High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

IEC 62271-102 Ed. 1.0 High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

Standard Number:  IEC 62271-102 Ed. 1.0
Title:  High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches
Language:  English and French
Replaced by Standard:  IEC 62271-102 Ed. 1.0

Replacing Standard:  IEC 60129 Ed. 3.0

Status:  Current
Publisher:  International Electrotechnical Commission (IEC)
Price:  
Number of Pages:187  

Description:Applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz. It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment. Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in IEC 60298, IEC 60466 and IEC 60517. Note- Disconnectors in which the fuse forms an integral part are not covered by this standard. This first edition cancels and replaces the third edition of IEC 60129 published in 1984, amendment 1 (1992) and amendment 2 (1996) and constitutes a technical revision. In addition, it replaces IEC 61128, IEC 61129 and IEC 61259, which are hereby withdrawn and cancelled. This bilingual version (2003-07) replaces the English version. The contents of the corrigenda of April 2002, May 2003, February 2005 and June 2014 have been included in this copy.  
Catalog:FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Normal and special service conditions
3 Definitions
3.1 General terms
3.2 Assemblies of switchgear and controlgear
3.3 Parts of assemblies
3.4 Switching devices
3.5 Parts of switching devices
3.6 Operation
3.7 Characteristic quantities
4 Ratings
4.1 Rated voltage (U[r])
4.2 Rated insulation level
4.3 Rated frequency (f[r])
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current (I[k])
4.6 Rated peak withstand current (I[p])
4.7 Rated duration of short-circuit (t[k])
4.8 Rated supply voltage of closing and opening
devices and of auxiliary and control circuits
(U[a])
4.9 Rated supply frequency of closing and opening
devices and of auxiliary circuits
4.10 Rated pressure of compressed gas supply for
insulation and/or operation
4.101 Rated short-circuit making current
4.102 Rated contact zone
4.103 Rated mechanical terminal load
4.104 Rated values of the bus transfer current
switching capability of disconnectors
4.105 Rated values of the induced current switching
capability of earthing switches
4.106 Rated values of mechanical endurance for
disconnectors and earthing switches
4.107 Rated values of electrical endurance for
earthing switches
5 Design and construction
5.1 Requirements for liquids in disconnectors and
earthing switches
5.2 Requirements for gases in disconnectors and
earthing switches
5.3 Earthing of disconnectors and earthing switches
5.4 Auxiliary and control equipment
5.5 Dependent power operation
5.6 Stored energy operation
5.7 Independent manual operation
5.8 Operation of releases
5.9 Low- and high-pressure interlocking and
monitoring devices
5.10 Nameplates
5.11 Interlocking devices
5.12 Position indication
5.13 Degree of protection by enclosures
5.14 Creepage distances
5.15 Gas and vacuum tightness
5.16 Liquid tightness
5.17 Flammability
5.18 Electromagnetic compatibility (EMC)
5.101 Special requirements for earthing switches
5.102 Requirements in respect of the isolating distance
of disconnectors
5.103 Mechanical strength
5.104 Operation of disconnectors and earthing switches -
Position of the movable contact system and its
indicating and signalling devices
5.105 Maximum force required for manual operation
5.106 Dimensional tolerances
6 Type tests
6.1 General
6.2 Dielectric tests
6.3 Radio interference voltage (riv) test
6.4 Measurement of the resistance of circuits
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand
current tests
6.7 Verification of the protection
6.8 Tightness tests
6.9 Electromagnetic compatibility tests (EMC)
6.101 Test to prove the short-circuit making performance
of earthing switches
6.102 Operating and mechanical endurance tests
6.103 Operation under severe ice conditions
6.104 Operation at the temperature limits
6.105 Test to verify the proper functioning of the
position-indicating device
6.106 Bus transfer current switching tests
6.107 Induced current switching tests
6.108 Bus-charging switching tests
7 Routine tests
7.1 Dielectric test on the main circuit
7.2 Dielectric test on auxiliary and control circuits
7.3 Measurement of the resistance of the main circuit
7.4 Tightness test
7.5 Design and visual checks
7.101 Mechanical operating tests
8 Guide to the selection of disconnectors and earthing
switches
8.101 General
8.102 Selection of rated values for normal service
conditions
9 Information to be given with enquiries, tenders and
orders
9.101 Information to be given with enquiries and orders
9.102 Information to be given with tenders
10 Rules for transport, storage, installation, operation and
maintenance
10.1 Conditions during transport, storage and
installation
10.2 Installation
10.3 Operation
10.4 Maintenance
11 Safety
11.1 Electrical aspects
11.2 Mechanical aspects
11.3 Thermal aspects
11.4 Operation aspects
Annex A (normative) Design and testing of
position-indicating devices
A.1 General
A.2 Normal and special service conditions
A.3 Definitions
A.4 Ratings
A.5 Design and construction
A.6 Type tests
A.7 Routine tests
Annex B (normative) Bus-transfer current switching by
disconnectors
B.1 General
B.2 Normal and special service conditions
B.3 Definitions
B.4 Ratings
B.5 Design and construction
B.6 Type tests
Annex C (normative) Induced current switching by earthing
switches
C.1 General
C.2 Normal and special service conditions
C.3 Definitions
C.4 Ratings
C.5 Design and construction
C.6 Type tests
Annex D (informative) Test voltage for the most
disadvantageous dielectric position of an earthing
switch during operation (temporary approach)
Annex E (normative) Special requirements for disconnectors
and earthing switches used in gas-insulated and/or
metal-enclosed switchgear
E.1 General
E.2 Normal and special service conditions
E.3 Definitions
E.4 Ratings
E.5 Design and construction
E.6 Type tests
E.7 Routine tests
E.8 Guide to the selection of disconnectors and
earthing switches
E.9 Information to be given with enquiries, tenders
and orders
E.10 Rules for transport, storage, installation,
operation and maintenance
Annex F (normative) Gas-insulated metal-enclosed switchgear
for rated voltages 72,5 kV and above - Requirements
for switching of bus-charging currents by
disconnectors
F.1 General
F.2 Normal and special service conditions
F.3 Definitions
Figures
Tables  
File Format:  PDF(Acrobat Reader) or Word version doc Document
File Size:  364KB
Tile in English:  High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

Full Text Information